MS20659-161 to -166,
Sizes 22 to 10
| Type: | Class 1 Uninsulated Terminals, Ring Tongue |
|---|---|
| Insulation: | N/A |
| Terminal Body & Sleeve: | Copper, ASTM B-152 |
| Plating: | Tin, ASTM B-545 |
| Max Temp Rating: | 175° C |
| AWG | WIRE SIZE (MM) | TERMINAL P/N | HX4 DIES (MULTI-CAVITY, 1 INDENT) | HX4 DIES (MULTI-CAVITY, 2 INDENT) | GMT SERIES TOOL (MIL-APPROVED, 1 INDENT) | GMT SERIES TOOL (2 INDENT) | DCT4 SERIES TOOL |
|---|---|---|---|---|---|---|---|
| #22-18 | 0.26-0.96 | MS20659-161 | Y554 | Y788 | GMT277 | GMT1005 | DCT4-105D |
| #22-18 | 0.26-0.96 | MS20659-162 | Y554 | Y788 | GMT277 | GMT1005 | DCT4-105D |
| #16-14 | 1.04-2.62 | MS20659-163 | Y554 | Y788 | GMT277 | GMT1005 | DCT4-105D |
| #16-14 | 1.04-2.62 | MS20659-164 | Y554 | Y788 | GMT277 | GMT1005 | DCT4-105D |
| #12-10 | 2.62-6.64 | MS20659-165 | Y554 | Y788 | GMT277 | GMT1005 | DCT4-105D |
| #12-10 | 2.62-6.64 | MS20659-166 | Y554 | Y788 | GMT277 | GMT1005 | DCT4-105D |
Note: Terminals with optional insulation support must use Y554 or GMT277. The Y788 and GMT1005 are not applicable for terminals with optional insulation support.
| AWG | TERMINAL P/N | BURNDY | HOLLINGSWORTH | MOLEX | PANDUIT | T&B | TYCO |
|---|---|---|---|---|---|---|---|
| #22-18 | MS20659-161 | – | – | – | – | – | – |
| #22-18 | MS20659-162 | – | – | – | – | – | – |
| #16-14 | MS20659-163 | – | – | – | – | – | – |
| #16-14 | MS20659-164 | – | – | – | – | – | – |
| #12-10 | MS20659-165 | YAV10-T7 | R3453B | – | P10-6R | C33 | – |
| #12-10 | MS20659-166 | – | R3223B | – | – | C75 | – |
NOTE: Component OEM’s instructions shall take precedence over the information presented in these charts. Wire ranges are for reference only